K-J50D
karestar
Good Quality Multiparam Portable K-J50D Hospital Equipment Operation Room ICU Multi-parameter ICU Patient Monitor
| Quick Details: |
| 7' TFT display, optional touch screen |
| PVI (Pleth Variability Index) |
| USB support PDF file export |
| Central station support Nurse Call by wire/wireless network |
| USB WIFI module can easy connect to CMS |
| USB data output with software to view data on computer |
| Digital SpO2 with excellent performance |
| Unique human voice alarm |
| 720 hours trend data and 12 hours of all waveforms |
| 20 languages include: English, French, Arabic, Hindi, Spanish, Portuguese,and etc |
| Standard Configuration | Option Configuration | |
| Main unit | 1 PC | ETCO2, Dual IBP, SPO2 monitoring |
| 5-lead/3-lead ECG Electrode | 1 PC | Suntech NIBP, Anesthetic gas module, Printer |
| NIBP cuff | 1 PC | Touch screen function |
| Disposable ECG Electrode | 5PC | Trolley, Wall mount |
| NIBP extension tube | 1 PC | Center monitoring system |
| Temperature probe | 1 PC | 12 lead ECG |
| Power Cable | 1 PC | |
| User Manual | 1 PC | |









| ECG | SPO2 | NIBP |
| Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V) | Measuring Range: 0 ~ 100 % | Pulse Rate Range 40 ~ 240 bpm |
| Gain: ×0.25, ×0.5, ×1, ×2 | Resolution: 1% | Static pressure accuracy ±3mmHg |
| Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal/Pediatric) Resolution: 1 BPM Accuracy: ±1% Sensitivity >200 μV(Peak to peak) | Accuracy: ±2 % for 70% ~ 100% 0% ~ 69% unspecified | Overpressure Protection Adult 300 mmHg Pediatric 240 mmHg Neonatal 150 mmHg |
| ST measurement: range: -2.0 ~ +2.0 mV Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater | Accuracy: ±2 % for 70% ~ 100% 0% ~ 69% unspecified | Measure and alarm range: Adult Mode SYS 40 ~ 280 mmHg DIA 10 ~ 220 mmHg MEAN 20 ~ 240 mmHg Pediatric Mode SYS 40 ~ 220 mmHg DIA 10 ~ 160 mmHg MEAN 20 ~ 170mmHg Neonatal Mode SYS 35 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg |
| Bandwidth: * Diagnostic: 0.05~130 Hz * Monitor: 0.5~40 Hz * Surgery: 1~20 Hz | Resolution: 1mmHg | |
| Differential Input Impedance > 5 M ohm | Accuracy: ±5mmHg |
| RESP | TEMP |
| Method: Impedance between RA-LL or RALA | Channel 1 |
| Differential Input Impedance >2.5 M ohm Respiration Impedance Range 0.3~3Ω Base Impedance Range 200Ω-2000Ω Bandwidth 0.3 ~ 2 Hz Gain ×0.25,×0.500,×1,×2,×4 | Measure and Alarm Range 0 ~ 50 ºC |
| Respiration Rate Measurement Range Adult 0 ~ 120 BrPM Neonatal / Pediatric 0 ~ 150 BrPM Resolution 1 BrPM Accuracy 0~6 BrPM: unspecified 7~150 BrPM: ±2 BrPM or ±2%, the greater Inspiriting current < 300 µA RMS max | Resolution 0.1ºC |
| Apnea Alarm 10 ~ 40 s | Accuracy ± 0.2ºC |